Controlling ultra low pressures in the inches of water, pascal, and millibar range can be quite difficult with traditional spring loaded regulators. The primary reason for this is due to how challenging it is to get valve parts to move with such low pressures. Using an electronic pressure regulator to control these pressures is a surprisingly accurate alternative. These electronic valves work by using a sensitive pressure transducer to sense minute changes in pressure and adjust the gas input and exhaust using solenoid valves. This method allows us to make much smaller adjustments in pressure than with a traditional regulator.

Method of Operation

The QPV electronic pressure regulator accepts an analog voltage (0 – 10V) or current (4 – 20 mA) signal. The unit will control proportional to the signal received. For example, with a 0 – 10 V = 0 – 1 psig / 68 millibar(g) unit, giving the unit a command of 5V tells the unit to go to 0.5 psig / 34 millibar(g) and giving the unit a command of 10V tells the unit to go to 1 psig / 68 millibar(g). Similarly, with a 4 – 20 mA = 0 – 1.0 psig / 68 millibar(g) unit, giving the unit a command of 12 mA tells the unit to go to 0.5 psig / 34 millibar(g) and giving the unit a command of 20 mA tells the unit to go to 1.0 psig / 68 millibar(g).

You can control the unit using your own PLC (programmable logic controller), a data acquisition device such as a DAQ with software such as LabVIEW by National Instruments, or even just a simple potentiometer (variable resistor).

Accuracy & Repeatability

The QPV series electronic pressure regulator has calibration ranges as low as 0 – 2 in H20 (0 – 500 Pa, 0 – 5 millibar(g)) with an accuracy of +/-0.25% of full scale calibration for pressure ranges above 1 psig / 68 millibar(g) and an accuracy of 1% of full scale for pressures ranges 1 psig / 68 millibar(g) and below.

The QPV1 will go to the desired pressure accurate to within ±1% of full scale calibrated range (for pressures below 1 psig / 68 millibar(g)). However, the repeatability spec of ±0.2% may be more applicable. This means that when given the same command, the unit will always be within the ±1% range of pressure, but will also be within 0.2% (of full scale) of the same pressure.

For Example: A 0 – 500 Pa calibrated unit.
Accuracy: Command of 5 VCD (or 12 mA) tells the unit to go to 250.0 Pa. It could land anywhere between 245 Pa and 255 Pa for an accuracy of +/- 5 Pa.
Repeatability: Say the unit hits 250.625 Pa, it will always be within ±0.2% of that number or, ±1 Pa. Very repeatable.

Below are some example calibration ranges and their associated accuracies and repeatabilities.

Calibration Range Accuracy Repeatability
0 – 2 in H20 ±0.02 in H20 ±0.004 in H20
0 – 10 in H20 ±0.10 in H20 ±0.02 in H20
0 – 500 Pa ±5 Pa ±1 Pa
0 – 5 millibar(g) ±0.05 millibar(g) ±0.01 millibar(g)
0 – 1 psig ±0.01 psig ±0.002 psig

Note: These are just example calibration ranges. The QPV can be calibrated to any pressure range from as low as 0 – 2 in H20 (0 – 500 Pa, 0 – 5 millibar(g)) to as high as 0 – 150 psig (0 – 1000 kPa, 0 – 10 bar(g)).

Photo of Equilibar QPV Electronic Pressure Regulator

Equilibar QPV low pressure electronic pressure regulator

 

photo of Equilibar QPV used as pilot regulator for Equilibar Back pressure regulator

Equilibar QPV is used as an electronic pilot regulator for an Equilibar GS Series back pressure regulator

Price and Availability

The QPV is surprisingly affordable and Equilibar offers a few models off the shelf for quick delivery. Custom calibration ranges and digital displays are available at 6-8 weeks lead time. Below is a list of these readily available part numbers:

Pressure Range Command Signal Monitor Signal Part Number
Low Pressure Options
0 – 10 in H20 / 254 mm H20 0 – 10 VDC 0 – 10 VDC QPV1MANEEZP10IWGAXL
0 – 1 psig / 68 millibar(g) QPV1MANEEZP1PSGAXL
0 – 10 psig / 689 millibar(g) QPV1MANEEZP10PSGAXL
Medium Pressure Options
0 – 50 psig / 3.4 bar(g) 0 – 10 VDC 0 – 10 VDC QPV1MANEEZP50PSGAXL
0 – 100 psig / 6.8 bar(g) QPV1MANEEZP100PSGAXL
0 – 150 psig / 10 bar(g) QPV1MANEEZP150PSGAXL
Vacuum Options
0 – 30 in Hg (vacuum) 0 – 10 VDC 0 – 10 VDC QPV1MANEEZN30IHGXAL
0 – 30 in Hg (vacuum) 4 – 20 mA DC 4 – 20 mA DC (Sourcing) QPV1MANISZN30IHGXAL

Equilibar News
Equilibar back after Hurricane Helene

The Equilibar team is back at work after Hurricane Helene

We’re happy to report that the Equilibar team is fully back at work this week following Hurricane Helene. While Helene wreaked havoc across the Western North Carolina mountains, we feel extremely lucky that all of our team members and their families are safe and our facilities had only minor issues. Once we could return to Read More